Description
The Lancer 115V 1.4A Motor AC SP UB 115/60 35W 1500 CW is the electrical agitating drive responsible for maintaining the ice bank’s water circulation. Operating with a Clockwise (CW) rotation, it drives the propeller that moves water across the evaporator coils to ensure uniform chilling and prevent the bath from freezing into a solid block.
Problem Solved: Restores circulation to prevent ‘bridging’—where ice freezes solid around the product coils—ensuring even cooling across all circuits. Fixes ‘warm soda’ issues caused by stagnant water baths.
Symptoms of Failure: A loud humming noise from the unit top without rotation, warm drinks at the tap despite the compressor running, or the motor frame becoming hot to the touch indicating a internal short.
Technician’s Note: Verify the capacitor health before replacing. A bound propeller caused by an ice bridge is the #1 cause of winding burnout; ensure the water level is correct and the bath is clear before powering on. Check rotation matches the CW requirement.Technical Specifications:
- Voltage: 115V / 60Hz
- Current/Power: 1.4A / 35W
- Rotation: CW (Clockwise)
- Series: 1500 Series Chilling Decks